HYDRO-HEATER
Sanitizing Sink Heaters
Food Rethermalizers/Bain-Marie Heaters
Installation &
Operating Manual
I&W #07.05.133.00
This manual contains important safety information
concerning the maintenance, use, and operation
of this product. Failure to follow the instructions
contained in this manual may result in serious injury.
If you are unable to understand the contents
of this manual, please bring it to the attention
of your supervisor. Do not operate this equipment
unless you have read and understood the contents
of this manual.
Este manual contiene importante información sobre
seguridad concerniente al mantenimiento, uso,
y operación de este producto. Cualquier falla
en el seguimiento de las instrucciones contenidas
en este manual puede resultar en un serio daño.
Si usted no puede entender el contenido de este
manual por favor pregunte a su supervisor. No opere
este equipo al menos que haya leído y comprendido
el contenido de este manual.
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - HYDRO-HEATER

HYDRO-HEATERSanitizing Sink HeatersFood Rethermalizers/Bain-Marie HeatersInstallation &Operating ManualI&W #07.05.133.00This manual contains i

Strany 2 - IMPORTANT OWNER INFORMATION

INSTALLATION8Form No. HHM-1103CAUTIONDo not overtighten unions or nuts. Overtighteningmay cause leaks.NOTE: A 3/4" (19 mm) hose or pipe may be co

Strany 3 - IMPORTANT SAFETY INSTRUCTIONS

NOTE–AUTO-FILL UNITS ONLY: When the tankwater level reaches the low water probe the display willshow the current water temperature and a small redligh

Strany 4

10Form No. HHM-1103OPERATIONNOTE: If steps 6-9 are interrupted or no changes are made for 15 seconds the controller will go back to its original setti

Strany 5 - MODEL DESCRIPTIONS

OPERATION11Form No. HHM-1103WaterTemp. AtStart-UpTemperature °F (°C) Water Heated To:WaterTemp. AtStart-UpTemperature °F (°C) Water Heated To:MINUTES

Strany 6

12Form No. HHM-1103MAINTENANCEGENERALWARNINGTo avoid any electrical shock hazard, or physicalburns turn the power OFF at the fuse disconnectswitch/cir

Strany 7

13Form No. HHM-1103MAINTENANCEOPTIONAL POWER FLUSH CLEANINGNOTE: Power Flush Kit sold separately.1. Turn power switch to OFF position.2. Connect one e

Strany 8

Form No. HHM-1103 14MAINTENANCEDELIMING INSTRUCTIONSCAUTIONInspect daily for lime and sediment buildup insideunit. Excessive amounts can affect unit p

Strany 9

Form No. HHM-110315MAINTENANCEWARNINGIf service is required on this unit, contact yourAuthorized Hatco Service Agent, or contact the Hatco Service Dep

Strany 10 - INSTALLATION

Form No. HHM-1103 16HATCO LIMITED WARRANTY1. PRODUCT WARRANTYHatco warrants the products that it manufactures (the “Products”) to be free from defects

Strany 11 - OPERATION

Form No. HHM-110317NOTES

Strany 12

Sanitizing Sink Heaters and Food Rethermalizers/Bain-Marie Heaters. We recommend all installation, operatingand safety instructions appearing in this

Strany 13

HATCO CORPORATIONP.O. Box 340500, Milwaukee, WI 53234-0500 U.S.A.(800) 558-0607 (414) 671-6350Parts & Service Fax (800) 690-2966 Int’l. Fax

Strany 14 - MAINTENANCE

CAUTIONSWater in the unit and holding vessel is very hot. Wear protective gloves and proper attirewhen operating to avoid injury.Do not use extension

Strany 15

IMPORTANT SAFETY INSTRUCTIONS2Form No. HHM-1103IMPORTANT! Read the following important safety instructions to avoid personal injury or death,and to av

Strany 16

Model 208 Volt 240 VoltFR2-3 NEMA 6-20P NEMA 6-20PFR2-4 NEMA 6-30P NEMA 6-30PSPECIFICATIONSMODEL DESCRIPTIONS3ALL MODELS The Hydro-Heater mounts to th

Strany 17

SPECIFICATIONS4Form No. HHM-1103Kilowatts Wire Sizing Fuse orModel Voltage (kW) Phase Amps AWG*† Circuit Breaker* Shipping Weight3CS2-3 208 3 1 14.5

Strany 18 - HATCO LIMITED WARRANTY

Kilowatts Wire Sizing Fuse orModel Voltage (kW) Phase Amps AWG*†Circuit Breaker* Shipping WeightFR2-3 208 3 1 14.5 12 20 24 lbs. (11 kg)FR2-4 208 4 1

Strany 19 - Form No. HHM-110317

SPECIFICATIONS6Form No. HHM-1103SIZING INFORMATIONHatco recommends the following guidelines be used to ensure proper operation and sanitation.For 3CS2

Strany 20

INSTALLATION7PLUMBINGAn adhesive backed paper template is shipped with the unit and is used to locate the sink strainer holes. Use the following proce